4. General Requirements
4.1 The contractor shall assess system and equipment test and measurement requirements during all phases of design, development,and production. The contractor shall identify all parameters that must be measured to ensure proper and accurate operation of the system and equipment. The system shall be designed,to reduce maintenance by keeping the frequency,number, and duration of the tests required to verify proper system operation to a minimum.

4.2 The contractor shall, by designing for testability, ensure ready accessibility of parameters which must be measured to verify proper and accurate system and equipment operation.

4.3 The contractor shall ensure that the system, equipment,and recommended support equipment technical documentation provide for measurement or verification of all parameters that must be measured in order to assure proper and accurate operation of the system and equipment.

Metadata
Document identifier
MIL-STD-1893A
Date published
1988-10-28
Language
English
Document type
military standard
Pages
14
Defines standard
Replaced/Superseded by document(s)
Cancelled by
Amended by
File MIME type Size (KB) Language Download
MIL STD- Calibration and Measurement Requirements.PDF application/pdf   721.05 KB English DOWNLOAD!
File attachments
Cover images
Introduction

1.1 Purpose:
This standard describes the requirement to provide means for calibration and measurement traceability of all system, subsystem,and equipment parameters that must be measured to ensure system and equipment operational integrity and accuracy. It describes the process of establishing measurement traceability from actual system and equipment level measurement requirements to the National Institute of Standards and Technology (NIST)or other approved measurement sources. These measurement requirements are traced through properly selected and calibrated test, measurement,and diagnostic equipment (TMDE) or appropriate measurement sensors, through individual Military Department or commercial calibration facilities, to approved national measurement standards.

1.2 Applicability:
The requirements of this standard apply to all systems, subsystems, and equipment that require measurement of any type to ensure proper operation.