Temperature measurements on the parts identified as high power dissipating parts and components, and those representative of part populations. A temperature versus time plot will be included that shows the temperature profile for each measurement point. The plot will indicate the temperature being commanded by the chamber controller and the actual chamber temperature.
Temperature-time to reach thermal stabilization for parts or components exhibiting high thermal inertia. (In addition to to high temperature measurements, these data shall also include low temperature measurements where ever temperature cycling is)
Defines standard
Replaced/Superseded by document(s)
Cancelled by
Amended by
File | MIME type | Size (KB) | Language | Download | |
---|---|---|---|---|---|
Thermal Survey Report.pdf | application/pdf | 17.95 KB | English | DOWNLOAD! |
Provides definitions
Introduction
This report covers the results of specified thermal survey tests performed on equipment to determine "hot spots" and temperature time to thermal stabilization. The report will be used by the procuring activity to determine readiness of the equipment for reliability.